6.2.2 RUN MODE RAMPS / Ramp output monitor PIN 21
This monitoring windo w is able to branch hop to 6.2.16 RUN MODE RAMPS / Ramping flag PIN 35.
Note that the RUN MODE RAMP may be active when the unit is in stop mode. See 6.2.1 RUN MODE RAMPS
/ Block diagram including JOG.
6.2.3 RUN MODE RA MPS / Forw ard up time PIN 22
6.2.4 RUN MODE RAMPS / Forw ard do wn time PIN 23
6.2.5 RUN MODE RA MPS / Reverse up time PIN 24
6.2.6 RUN MODE RA MPS / Reverse do wn time PIN 25
RUN MODE RAMPS 3
24)REVERSE UP TIME
24)REVERSE UP TIME
10.0 SECS
PARA METER RANGE DEFAULT PIN
REVERSE UP TIME 0.1 to 60 0.0 seconds 10.0 secs 2 4
Sets the ramp time for 0-100 %
of the reverse -ve reference.
R R
RUN MODE RAMPS 3
21)RA MP OP M ONIT OR
21)RA MP OP M ONITOR
0.00%
PARA METER RANGE PIN
RA MP OP M ONITOR + /-100.00% 21
Allo ws the output level of the ramp block
to be monitored.
R
R
RUN MODE RAMPS 3
22)FORW ARD UP TIME
22)FORW ARD UP TIME
10.0 SECS
PARA METER RANGE DEFAULT PIN
FORW ARD UP TIME 0.1 to 600.0 seconds 10.0 secs 22
Sets the ramp time for 0-100 %
of the forward + ve reference.
R
R
RUN MODE RAMPS 3
23)FORW ARD DO W N TIME
23)FORW ARD DO W N TIME
10.0 SECS
PARA METER RANGE DEFAULT PIN
FORW ARD DO W N TIME 0.1 to 600.0 seconds 10.0 secs 23
Sets the ramp time for 100-0 %
of the forward + ve reference.
RR
RUN MODE RAMPS 3
25)REVERSE DO WN TIME
25)REVERSE DO WN TIME
10.0 SECS
PARA METER RANGE DEFAULT PIN
REVERSE DO WN TIME 0.1 to 600.0 seconds 10.0 secs 2 5
Sets the ramp time for 100-0 %
of the reverse -ve reference.
RR