EasyManua.ls Logo

Cessna 182 1978 - Page 109

Cessna 182 1978
680 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL
182
&
T182
SERIES
SERVICE
MANUAL
CESSNA
PROGRESSIVE
CARE
MODEL
182
&
T182
OPERATION
NO.
4
MECHANIC
INSPECTOR
REMARKS
13.
Aileron
Controls
- Check
freedom
of
movement
and
proper
operation
through
full
travel
with
and
with-
out flaps
extended.
14.
Flap
Structure,
Linkage,
Bellcranks,
Pulleys,
and
Pul-
ley
Brackets
- Check
for
condition,
operation,
and
security.
15.
Flaps
and
Cables
-
Check
cables
for
proper
tension,
routing, fraying,
corrosion,
and
turnbuckle
safety.
Check
travel
if
cable
tension
requires
adjustment.
16.
Flap
Motor,
Actuator,
and
Limit
Switches
(electric
flaps)
-
Check
wiring
and
terminals
for condition
and
security.
17.
Flaps
-
Check
tracks,
rollers,
and
control
rods
for
se-
curity
of
attachment.
Check
operation.
18.
Flap
Actuator
Threads
-
Clean
and
lubricate.
19.
Fuel
System
-
Inspect
plumbing
and
components
for
mounting
and
security.
20.
Fuel
Bladders
- Check
for
leaks
and
security,
condi-
tion
of
fuel
caps,
adapters,
and
placards.
21.
Integral
Fuel
Tanks
- Check
for
evidence
of
leakage
and
condition
of
fuel
caps
and
placards.
22.
Metal
Lines,
Hoses,
Clamps,
and
Fittings
-
Check
for
leaks,
condition,
and
security.
Check
for
proper rout-
ing
and
support.
23.
Wing
Structure
-
Inspect
spars,
ribs,
skins,
and
stringers
for
cracks,
wrinkles,
loose rivets, corro-
sion,
or
other
damage.
24.
General
Airplane
and
System
Wiring
-
Inspect
for
proper
routing,
chafing, broken
or
inadequate
clamps,
and
sharp
bends
in
wiring.
Sheet
11
of
14
Revision
1
2-77

Table of Contents