PurposeCommand or Action
Returns to privileged EXEC mode.exit
Example:
Device(config)# exit
Step 7
Enables cross-checking between remote MEPs in the
domain and MEPs learned through CCMs.
ethernet cfm mep crosscheck {enable | disable} level
{level-id | level-id-level-id [,level-id-level-id]} vlan {vlan-id
| any | vlan-id-vlan-id [,vlan-id-vlan-id]}
Step 8
Example:
Device# ethernet cfm mep crosscheck enable level 4
vlan 100
Example
The following example configures cross-checking on an inward facing MEP (U-PE A):
U-PE A
ethernet cfm domain ServiceProvider level 4
mep crosscheck mpid 402 vlan 100
!
ethernet cfm mep crosscheck start-delay 60
The following example enables cross-checking on an inward facing MEP (U-PE A):
U-PE A
U-PEA# ethernet cfm mep crosscheck enable level 4 vlan 100
Configuring and Enabling Cross-Checking for an Inward Facing MEP on the U PE-B
Perform this task to configure and enable cross-checking for an inward facing MEP. This task requires you
to configure and enable cross-checking on two devices. This task is optional.
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
ethernet cfm domain domain-name level level-id
4.
mep crosscheck mpid id vlan vlan-id [mac mac-address]
5.
exit
6.
ethernet cfm mep crosscheck start-delay delay
7.
exit
8.
ethernet cfm mep crosscheck {enable | disable} level {level-id | level-id-level-id [,level-id-level-id]}
vlan {vlan-id | any | vlan-id-vlan-id [,vlan-id-vlan-id]}