EasyManuals Logo

Cisco ASR 920 series Configuration Guide Ethernet Router

Cisco ASR 920 series
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #278 background imageLoading...
Page #278 background image
PurposeCommand or Action
Sets the amount of time that CFM traceroute cache entries
are retained.
ethernet cfm traceroute cache hold-time minutes
Example:
Device(config)# ethernet cfm traceroute cache
hold-time 60
Step 10
Enables SNMP trap generation for Ethernet CFM mep-up,
mep-down, config, loop, and cross-connect events.
snmp-server enable traps ethernet cfm cc [mep-up]
[mep-down] [config] [loop] [cross-connect]
Example:
Device(config)# snmp-server enable traps ethernet
Step 11
cfm cc mep-up mep-down config loop cross-connect
Enables SNMP trap generation for Ethernet CFM
mep-unknown, mep-missing, and service-up continuity
snmp-server enable traps ethernet cfm crosscheck
[mep-unknown] [mep-missing] [service-up]
Step 12
check events in relation to the cross-check operation
Example:
Device(config)# snmp-server enable traps ethernet
cfm crosscheck mep-unknown
between statically configured MEPs and those learned via
CCMs.
Returns the device to privileged EXEC mode.end
Example:
Device(config)# end
Step 13
Example:
Provisioning Service (CE-A)
Perform this task to set up service for Ethernet CFM. Optionally, when this task is completed, you may
configure and enable the cross-check function. To perform this optional task, see Configuring and Enabling
the Cross-Check Function (CE-A), on page 267.
Carrier Ethernet Configuration Guide (Cisco ASR 920 Series)
260
Configuring Ethernet CFM
Configuring Ethernet CFM

Table of Contents

Other manuals for Cisco ASR 920 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 920 series and is the answer not in the manual?

Cisco ASR 920 series Specifications

General IconGeneral
Form Factor1RU
Operating SystemCisco IOS XE
ModelASR 920 series
Memory4 GB DRAM
Power SupplyAC or DC
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Relative Humidity5% to 95% non-condensing
MTBFVaries by model
ManagementCLI, SNMP

Related product manuals