2-77
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 2 Alarm Troubleshooting
2.7.74 DBOSYNC
Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC 1 800 553-2447.
2.7.74 DBOSYNC
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: NE
The Standby Database Out Of Synchronization alarm occurs when the standby TCC2/TCC2P database
does not synchronize with the active database on the active TCC2/TCC2P.
Caution If you reset the active TCC2/TCC2P while this alarm is raised, you lose current provisioning.
Clear the DBOSYNC Alarm
Step 1 Save a backup copy of the active TCC2/TCC2P database. Refer to the “Maintain the Node” chapter in
the Cisco ONS 15454 Procedure Guide for procedures.
Step 2 Make a minor provisioning change to the active database to see if applying a provisioning change clears
the alarm:
a. In node view, click the Provisioning > General > General tabs.
b. In the Description field, make a small change such as adding a period to the existing entry.
The change causes a database write but does not affect the node state. The write could take up to a
minute.
Step 3 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC 1 800 553-2447.
2.7.75 DCU-LOSS-FAIL
For information about this alarm or condition, refer to the “Alarm Troubleshooting” chapter in the
Cisco ONS 15454 DWDM Troubleshooting Guide. This guide discusses all DWDM alarms.
2.7.76 DISCONNECTED
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: SYSTEM
The Disconnected alarm is raised when CTC has been disconnected from the node. The alarm clears
when CTC reconnects to the node.