EasyManua.ls Logo

Cisco ONS 15454 - 1.2.1 Perform a Facility Loopback on a Source Electrical Port (West to East); Create the Facility Loopback on the Source DS-1, DS-3, DS3 N-12, DS3 i-N-12, or EC1 Port

Cisco ONS 15454
558 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-10
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 1 General Troubleshooting
1.2.1 Perform a Facility Loopback on a Source Electrical Port (West to East)
Note Facility, hairpin, and terminal loopback tests require on-site personnel.
1.2.1 Perform a Facility Loopback on a Source Electrical Port (West to East)
The facility loopback test is performed on the node’s source electrical port in the network circuit; in this
example, the DS-N port in the source node. Completing a successful facility loopback on this port
isolates the cabling, the electrical card, and the EIA as possible failure points. Figure 1-11 shows an
example of a facility loopback on a source DS-N port.
Figure 1-11 Facility Loopback on a Circuit Source DS-N Port
Caution Performing a loopback on an in-service circuit is service-affecting. To protect traffic, apply a lockout or
Force switch to the target loopback port. For more information about these operations, refer to the
“Maintain the Node” chapter in the Cisco ONS 15454 Procedure Guide.
Note Facility loopbacks require on-site personnel.
Note ONS 15454 DS-3 terminal loopbacks do not transmit an AIS in the direction away from the loopback.
Instead of AIS, a continuance of the signal transmitted into the loopback is provided. A DS3/EC1-48
card can be provisioned to transmit AIS for a terminal loopback if desired.
Depending on your card type, complete the “Create the Facility Loopback on the Source DS-1, DS-3,
DS3N-12, DS3i-N-12, or EC1 Port” procedure on page 1-10 or the “Create the Facility Loopback on the
Source DS3E or DS3XM Port” procedure on page 1-11, then test and clear the loopbacks as instructed.
Create the Facility Loopback on the Source DS-1, DS-3, DS3N-12, DS3i-N-12, or EC1 Port
Step 1 Connect an electrical test set to the port you are testing.
Use appropriate cabling to attach the Tx and Rx terminals of the electrical test set to the EIA connectors
or DSx panel for the port you are testing. The Tx and Rx terminals connect to the same port.
Step 2 Adjust the test set accordingly. (For specific procedures to use the test set equipment, consult the
manufacturer.)
Step 3 In node view, double-click the card to open the card view.
Source
ONS Node
Destination
ONS Node
55262
DS-N OC-NXC OC-N DS-NXC
Test Set

Table of Contents