2-94
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 2 Alarm Troubleshooting
2.7.100 EXT
2.7.100 EXT
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: ENVALRM
A Failure Detected External to the NE alarm occurs because an environmental alarm is present. For
example, a door could be open or flooding could have occurred.
Clear the EXT Alarm
Step 1 In node view double-click the AIC-I card to open the card view.
Step 2 Double-click the Maintenance > External Alarms tab.
Step 3 Follow your standard operating procedure to remedy environmental conditions that cause alarms. The
alarm clears when the situation is remedied.
Step 4 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC 1 800 553-2447.
2.7.101 EXTRA-TRAF-PREEMPT
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: OCN
An Extra Traffic Preempted alarm occurs on OC-N cards in two-fiber and four-fiber BLSRs when
low-priority traffic directed to the protect system has been preempted by a working system protection
switch.
Clear the EXTRA-TRAF-PREEMPT Alarm
Step 1 Verify that the protection switch has occurred by checking the Conditions tab.
Step 2 If a ring switch has occurred, clear the ring switch on the working system by following the appropriate
alarm in this chapter. For more information about protection switches, refer to the “2.9.2 Protection
Switching, Lock Initiation, and Clearing” section on page 2-262 or the “Maintain the Node” chapter in
the Cisco ONS 15454 Procedure Guide.
Step 3 If the alarm occurred on a four-fiber BLSR and the span switch occurred on this OC-N, clear the span
switch on the working system.
Step 4 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC 1 800 553-2447 in order to report a Service-Affecting (SA)
problem.
2.7.102 FAILTOSW
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)