2-267
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 2 Alarm Troubleshooting
2.9.2 Protection Switching, Lock Initiation, and Clearing
Clear an External Switching Command on a Path Protection Span
Note If the ports terminating a span are configured as revertive, clearing a Force or Manual switch to protect
moves traffic back to the working port. If ports are not configured as nonrevertive, clearing a Force
switch to protect does not move traffic back.
Step 1 Log into a node on the network. If you are already logged in, continue with Step 2.
Step 2 Right-click a network span and choose Circuits.
The Circuits on Span dialog box shows the path protection circuits, including circuit names, locations,
and a color code showing which circuits are active on the span.
Step 3 Initiate a Force switch for all circuits on the span:
a. Click the Perform Path Protection span switching field.
b. Choose Clear from the drop-down list.
c. Click Apply.
d. In the Confirm Path Protection Switch dialog box, click Ye s.
e. In the Protection Switch Result dialog box, click OK.
In the Circuits on Span dialog box, the switch state for all circuits is Clear. Unprotected circuits do
not switch.
Initiate a Force Ring Switch on a BLSR
Step 1 Log into a node on the network. If you are already logged in, continue with Step 2.
Step 2 From the View menu choose Go to Network View.
Step 3 In network view, click the Provisioning > BLSR tabs.
Step 4 Click the row of the BLSR you are switching, then click Edit.
Step 5 Right-click a BLSR node west port and choose Set West Protection Operation.
Step 6 In the Set West Protection Operation dialog box, choose Force Ring from the drop-down list.
Step 7 Click OK.
Step 8 Click Yes in the two Confirm BLSR Operation dialog boxes that appear.
Initiate a Force Span Switch on a Four-Fiber BLSR
Step 1 Log into a node on the network.
Step 2 From the View menu choose Go to Network View.
Step 3 In network view, click the Provisioning > BLSR tabs.
Step 4 Click the row of the BLSR you are switching, then click Edit.