2-197
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 2 Alarm Troubleshooting
2.7.320 PMI
Step 3 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC 1 800 553-2447 in order to report a Service-Affecting (SA)
problem.
2.7.320 PMI
For more information about the PMI condition, refer to the “Alarm Troubleshooting” chapter in the
Cisco ONS 15454 DWDM Troubleshooting Guide.
2.7.321 PORT-FAIL
For more information about the PORT-FAIL alarm, refer to the “Alarm Troubleshooting” chapter in the
Cisco ONS 15454 DWDM Troubleshooting Guide.
2.7.322 PORT-MISMATCH
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Objects: CE-MR-10, ML-MR-10, FC_MR-4
The Pluggable PORT-MISMATCH alarm applies to FC_MR-4, ML-MR-10, and CE-MR-10 Ethernet
cards.
For the ML-MR-10 and CE-MR-10 cards the alarm indicates either of the following:
The provisioned payload, speed, or duplex configured on the port does not match that of the SFP
plugged into the port.
A non-supported SFP is plugged into the port.
For the FC_MR-4 card the alarm indicates that a non-supported GBIC is plugged into the port.
Clear the PORT-MISMATCH Alarm
To clear the alarm on the CE-MR-10 card, either plug-in a supported SFP into the CE-MR-10 port or
follow these steps to provision the correct payload, speed, or duplex:
1. In node view (single-shelf mode) or shelf view (multishelf mode), double-click the CE-MR-10
card to open the card view.
2. Click the Provisioning > Ether Ports tabs.
3. Specify correct values in the Expected Speed and Expected Duplex fields to match the SFP
configuration.
4. Click Apply.
To clear the alarm on the FC_MR-4 card, plug-in a supported GBIC into the FC_MR-4 port and follow
these steps to provision the media type:
1. In node view (single-shelf mode) or shelf view (multishelf mode), double-click the FC_MR-4
card graphic to open the card.
2. Click the Provisioning > Port > General tabs.