Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 2 Alarm Troubleshooting
2.7.273 MEA (EQPT)
Clear the MEA (BIC) Alarm
Step 1 Click the Provisioning > Inventory tabs to determine your backplane model. If the backplane is not a
15454-SA-HD, replace the backplane or do not attempt to use high-density DS-3 cards. Table 2-18 lists
the BICs that are compatible with various backplanes.
Step 2 If you determine that your BIC type and backplane are compatible despite the MEA alarm, or if the alarm
does not clear after you resolve the incompatibilities, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC 1 800 553-2447 in order to
report a Service-Affecting (SA) problem.
2.7.273 MEA (EQPT)
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
Table 2-18 BIC Compatibility Matrix
BIC Type Part No.
BICs that work with the newer and older
backplanes
MANUF_EQPT_ID_BIC_A_SMB_HD_BP
MANUF_EQPT_ID_BIC_B_SMB_HD_BP
MANUF_EQPT_ID_BIC_A_BNC_24_HD_BP
MANUF_EQPT_ID_BIC_A_BNC_48_HD_BP
MANUF_EQPT_ID_BIC_B_SMB
MANUF_EQPT_ID_BIC_B_SMB_ALT
MANUF_EQPT_ID_BIC_B_BNC_24
MANUF_EQPT_ID_BIC_B_BNC_48
New HD BICs that work only with the new
backplanes
MANUF_EQPT_ID_BIC_A_UNIV_VERT
MANUF_EQPT_ID_BIC_B_UNIV_VERT
MANUF_EQPT_ID_BIC_A_UNIV_HORIZ
MANUF_EQPT_ID_BIC_B_UNIV_HORIZ
MANUF_EQPT_ID_BIC_A_MINI_BNC_HD_BP
MANUF_EQPT_ID_BIC_B_MINI_BNC_HD_BP
High-density BICs that work only with
15454-SA-HD
MANUF_EQPT_ID_BIC_A_SMB
MANUF_EQPT_ID_BIC_A_SMB_ALT
MANUF_EQPT_ID_BIC_A_BNC_24
MANUF_EQPT_ID_BIC_A_BNC_48