4-9
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-2102 The forced switch could not be removed for some circuits. You
must switch these circuits manually.
The forced switch could not be removed for
some circuits. You must switch these
circuits manually.
EID-2103 An error occurred while upgrading the span. There was an error during the span upgrade.
EID-2104 The circuits cannot be switched back because one or both nodes
are not reachable.
This error occurs during the path protection
span upgrade procedure.
EID-2106 The node name cannot be empty. You must supply a name for the node.
EID-2107 An error occurred while adding {0}. The host is unknown. There was an error adding the specified
item.
EID-2108 {0} is already in the network. The specified item exists in the network.
EID-2109 The node is already in the current login group. The node you are trying to add is already
present in the current login group.
EID-2110 Please enter a number between 0 and {0}. You must enter a number in the range
between 0 and the specified value.
EID-2111 This node ID is already in use. Please choose another. Select a node ID that is not in use.
EID-2113 The extension byte for the ring cannot be set.
{0}
CTC cannot set the BLSR/MS-SPRing
extension byte.
EID-2114 A card communication failure occurred during the operation. This error can occur during an attempt to
apply a BLSR protection operation to a line.
EID-2115 An error occurred during the operation.
{0}
There was an error in applying the specified
operation.
EID-2116 The extension byte setting for the ring is invalid.
{0}
The extension byte set for the specified ring
is invalid.
EID-2118 The ring cannot be deleted.
A protection operation is set. All protection operations must be
clear for ring to be deleted.
Clear all the protection operations for the
ring before deleting it.
EID-2119 {0} cannot be deleted because a protection switch is in effect.
Please clear any protection operations, ensure that the reversion
time is not "never" and allow any protection switches to clear
before trying again.
Clear all protection operations or switches
before deleting the ring.
EID-2120 The following nodes could not be unprovisioned
{0}
Therefore you will need to delete this {1} again later.
The specified nodes could not be
unprovisioned. Try deleting this BLSR or
MS-SPRing later.
EID-2121 The ring cannot be upgraded.
{0}
CTC cannot upgrade the specified ring.
EID-2122 The ring speed for is inadequate for the upgrade procedure.
Only {0} (or higher) {1} can be upgraded to four-fiber.
You have selected an incorrect ring speed
for upgrade. Only rings within the specified
parameters can be upgraded to 4-fiber
BLSR.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description