DMD1050TS Satellite Modem Board
Revision 1
Appendix C C–9 MN-DMD1050TS
4. If the ping is unsuccessful, the screen shows:
C:\>ping 172.18.100.215
Pinging 172.18.100.215 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Ping statistics for 172.18.100.215:
Packets: Sent = 4, Received = 0, Lost = 4 (100%
loss),
5. For an unsuccessful response, check these items:
a. The correct cables are connected to the Ethernet port, and they are secured.
b. The Link Light is illuminated.
c. The IP Address matches the Modem’s IP Address.
d. The Server and Modem are on the same subnet.