EasyManuals Logo
Home>Danfoss>DC Drives>FC 300

Danfoss FC 300 Design Guide

Danfoss FC 300
309 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
FC 300 Design Guide
FC 300 Selection
Analog output:
Number of programmable a nalog outputs ......................................................................................... 1
Terminal number ......................................................................................................................... 42
Current range at analog output ....................................................................................... 0/4 - 20 mA
Max. load to common at analog output ..................................................................................... 500
Accuracy on analog output ..................................................................... Max. error: 0.5% of full scale
Resolution on analog o utput .................................................................................................... 12 bit
The analog output is galvonically isolated from the supp ly voltage (PELV) and other high-v oltage terminals.
Control card, RS-485 serial communication:
Terminal number .............................................................................. 68 (P,TX+, RX+), 69 (N,TX-, RX-)
Terminal number 61 ......................................................................... Common for terminals 6 8 and 69
The RS-485 serial communication circuit is functionally sep arated from other central circuits
and galvanically iso lated from the supplier voltage (PELV).
Digital outp u t:
Programmable digital/pulse outputs ................................................................................................2
Terminal number ................................................................................................................ 27, 29
1)
Voltage level at digital/frequency output ................................................................................. 0 - 24 V
Max. output current (sink or source) ........................................................................................ 40 mA
Max. load at frequency output ................................................................................................... 1 k
Max. capacitive load at frequency output .................................................................................... 10 nF
Minimum output frequency at frequency output ........................................................................... 0 Hz
Maximum output frequency at frequency output ....................................................................... 32 kHz
Accuracy of frequency output .................................................................. Max. e rror: 0.1% of full scale
Resolution of output frequency ................................................................................................. 12 bit
1) Terminal 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supp ly voltage (P ELV) and other high-voltage terminals.
Control card, 24 V DC output:
Terminal number ................................................................................................................... 12, 13
Max. load ...................................................................................... FC 301: 130 mA / FC 302: 200 mA
The 24 V DC supply is g alv o nically is olated from the supply voltage (PELV), but has the sa me
potential as the analog and digital inputs and outputs.
Relay outputs:
Programmable relay outputs ............................................................................. FC 301: 1 / FC 302: 2
Relay 01 Terminal number .............................................................................. 1-3 (break), 1-2 (make)
Max. terminal load (AC-1)
1)
on 1-3 (NC), 1-2 (NO) (Resistive load) .................................... 240 V AC, 2 A
Max. terminal load (AC-15)
1)
(Inductive load @ cosφ 0.4) ............................................. 240 V AC, 0.2 A
Max. terminal load (DC-1)
1)
on 1-2 (NO), 1-3 (NC) (Resistive load) ...................................... 60 V DC, 1A
Max. terminal load (DC-13)
1)
(Inductive load) ................................................................. 24 V DC, 0.1A
Relay 02 (FC 302 only) Terminal number .......................................................... 4-6 (break), 4-5 (make)
Max. terminal load (AC-1)
1)
on 4-5 (NO) (Resistive load) .................................................. 400 V AC, 2 A
Max. terminal load (AC-15)
1)
on 4-5 (NO) (Inductive load @ cos φ 0.4) ............................ 240 V AC, 0.2 A
Max. terminal load (DC-1)
1)
on 4-5 (NO) (Resistive load) ................................................... 80 V DC, 2 A
Max. terminal load (DC-13)
1)
on 4-5 (NO) (Inductive load) .............................................. 24 V DC, 0.1A
Max. terminal load (AC-1)
1)
on 4-6 (NC) (Resistive load) ................................................. 240 V AC, 2 A
Max. terminal load (AC-15)
1)
on 4-6 (NC) (Inductive load @ cosφ 0.4) ............................ 240 V AC, 0.2A
Max. terminal load (DC-1)
1)
on 4-6 (NC) (Resistive load) ................................................... 50 V DC, 2 A
63
MG.33.B6.22 - VLT is a registered Danfoss trademark

Table of Contents