Logical Combination
Reference Manual 91
Results Without Priority Filter:
Group 1 - read either code 1 or 2 = Good Read; read both code 1 and 2 =
Multiple Read
Group 2 - read either code 5 or 3 or 4 = Good Read; read any combination =
Multiple Read
Group 3 - read either code 8 or 6 or 7 = Good Read; read any combination =
Multiple Read
Results With Priority Filter:
Filter Enabled on Groups = 1,3
Filter Type =Custom
Custom Filter Pattern String = 1^2&8^6|7 (2 groups)
Group 1 - read code 1 = Good Read independent from reading code 2
Group 2 - read either code 5 or 3 or 4 = Good Read; read any combination =
Multiple Read
Group 3 - read code 8 = Good Read independent from reading code 6 or 7; no read
on code 8 and read either code 6 or 7 = Good Read; no read on code 8 and read
both code 6 and 7 = Multiple Read
Priority Filter Advanced String
Enter the character string (see above).
2. When you have finished making changes, click Update All to save all pend-
ing changes, click Reset All to revert to all previously saved values, and click
Reset Page to revert to previous saved values on the current page.