Energy Saving
Reference Manual 159
more than the programmed timeout, Energy Saving will be activated.
Deactivation Encoder Timeout
Select a second or minute value from the drop-down list. This parameter is
available only when the encoder is used for Energy Saving deactivation. If the
encoder runs for at least the programmed timeout, Energy Saving will be
deactivated.
Use Digital Input For
Select None, Deactivation, Activation, or Activation and Deactivation from the drop-
down list. This parameter allows defining the function to be performed by a digital
input:
None: No function is performed by the digital input.
Deactivation: The digital input is used to deactivate Energy Saving. Thus, the
motor and laser of all network scanners will be turned on.
Activation: The digital input is used to activate Energy Saving. Thus, the
motor and laser of all network scanners will be turned off.
Activation and Deactivation: The digital input is used to both activate and
deactivate Energy Saving. Thus, the motor and laser of all network scanners
will be turned on/off.
Select Digital Input
Select a digital input from the drop-down list. This parameter defines the digital
input to be used for activating/deactivating Energy Saving.
Select Input Type
Select Edge or Level from the drop-down list.
Use Main Serial Port For
Select None, Deactivation, Activation, or Activation and Deactivation from the drop-
down list. This parameter allows defining the function to be performed by Main
Serial Port:
None: No function is performed by the digital input.
Deactivation: The digital input is used to deactivate Energy Saving. Thus, the
motor and laser of all network scanners will be turned on.
Activation: The digital input is used to activate Energy Saving. Thus, the
motor and laser of all network scanners will be turned off.
Activation and Deactivation: The digital input is used to both activate and
deactivate Energy Saving. Thus, the motor and laser of all network scanners
will be turned on/off
Header
Click to activate the Text Entry Tool and create a Header (up to 128 bytes) to
define a header (1 byte) and transmit it as a block preceding the activation/
deactivation string sent to a Master or Stand Alone scanner. Use characters from
NUL (00H) to ~ (7EH). Click Submit to save your text to the origin window text field,
or click Cancel to return to origin window without transferring text.
Terminator
Click to activate the Text Entry Tool and create a Terminator to define a
terminator (1 byte) and transmit it as a block following the activation/deactivation
string sent to the Master or Stand Alone scanner. Use characters from NUL (00H) to
~ (7EH). Click Submit to save your text to the origin window text field, or click
Cancel to return to origin window without transferring text.
Activation String
Click to activate the Text Entry Tool and create a string that defines the
characters to be transmitted within the output message to activate Energy Saving.
This parameter is available only when a communication channel has been selected to
perform a specific function.
This parameter is available only when a communication channel has been selected to
perform a specific function.
This parameter is available only when a communication channel has been selected to
perform a specific function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DX8210 and is the answer not in the manual?

Datalogic DX8210 Specifications

General IconGeneral
BrandDatalogic
ModelDX8210
CategoryBarcode Reader
LanguageEnglish

Related product manuals