Error Codes and Resolutions
Reference Manual 275
193
Fieldbus
Config
Error
Error
Error configur-
ing fieldbus
module.
- Unable to
communicate
to the module.
- Confirm that
the unit is not
communicating
to the host.
- Confirm that
the fieldbus
parameters are
configured prop
-
erly (see section
“Fieldbus” on
page 116).
- Replace fieldbus
module.
195
Fieldbus
DHCP Error
Error
Profinet mod-
ule had a DHCP
error.
- Unable to
acquire an IP
address.
- Confirm that
the unit is not
communicating
to the host.
- Confirm that
the fieldbus
parameters are
configured prop
-
erly (see section
“Fieldbus” on
page 116).
- Replace fieldbus
module.
205
APD Tem-
perature
Error
Error
APD Tempera-
ture sensor is
not working. A
fluctuation in
the scanner's
temperature
can have an
adverse effect
on several inter
-
nal functions of
the scanner.
The scanner
monitors the
temperature,
and if it is
erratic, this
error is posted.
- The scanner
may experi
-
ence an
increase in no-
reads.
- The scanner
may start
missing the
transmit point.
1. Cycle power on
the scanner;
2. Wait until the
unit has time to
cool down.
3. Restart the
scanner and
monitor it to
determine
whether the
error reoccurs.
This is an internal
failure and is not
field serviceable.
- Replace scanner.
Error
Code
Descrip-
tion
Sever-
ity
Explanation Symptom Troubleshooting Action required