ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
147
Code 39 Set Length 1
This feature specifies one of the barcode lengths for Code 39 Length Control.
Length 1 is the minimum
label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. Length includes the barcode’s data char-
acters only. The length can be set from 0 to 50 characters.
Table 2 provides examples for setting Length 1. See page 294 for detailed
instructions on setting this feature.
Table 2. Code 39 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 39 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
DEFAULT
02 = Length 1 is 2 Characters