Scanning Features
Product Reference Guide
307
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state
once the state is entered. The range for this setting is from 1 to 255 seconds in
1-second increments.
Follow these instructions
to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 =
0
00, 5 = 005, 20 = 020, etc.
3. Go to page 108 and scan the ENTER/EXIT PROGRAMMING MODE barcode
to enter Programming Mode.
4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad,
that represent the duration which was determined in the steps above. You
wil
l hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry
string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table 42 for some examples of how to set
this feature.
Table 42. Scanning Active Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25
mi
n.)
2 Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE