ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
159
Code 128 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very
aggressive to very conservative depending on a particular customer’s needs.
See page 294 for more information on this feature.
Code 128 Decoding Level = 1 (Conservative)
Code 128 Decoding Level = 2
Code 128 Decoding Level = 3
DEFAULT
Code 128 Decoding Level = 4
Code 128 Decoding Level = 5 (Aggressive)
Code 128 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the Code 128 symbology. See page 294 for more information..
DEFAULT
Code 128 Length Control = Variable Length
Code 128 Length Control = Fixed Length