ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
197
Datalogic 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length
Control. Length 2 is the maximum label length if in Variable Length Mode, or
the second fixed length if in Fixed Length Mode. The length includes the bar-
code’s check and da
ta characters.
The length can be set from 2 to 50 characte
rs. A setting of 0 specifies to ignore
this length (only one fixed length).
Table 15 provides examples for setting Length 2. See page 295 for detailed
instructions on setting this feature.
Table 15. Datalogic 2 of 5 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
Ignore This
Length
4 Characters 14 Characters 50 Characters
2
Pad with leading zeroes to
yield two digit
s
00 04 14 50
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘4’ ‘1’ and ‘4’ ‘5’ AND ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE
Select Datalogic 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters