ENTER/EXIT PROGRAMMING MODE
234 Gryphon™ I GD4132/GM4102/GBT4102
Code 93 Set Length 2
This feature specifies one of the barcode lengths for Code 93 Length Control.
Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. Length includes the barcode’s check,
data, and full-ASCII shift characters. The
length does not include start/stop
characters. The length can be set from 1 to 50 characters. A setting of 0 speci-
fies to ignore this length (only one fixed length).
Table 23 provides examples for setting Length 2. See page 295 for detailed
instructions on setting this feature.
Table 23. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5 ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters