288 Gryphon™ I GD4132/GM4102/GBT4102
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmis-
sion due to a retry condition. The selectable range is from 1 to 254 retries. A
se
lection of 0 disables the count, and a selection of 255 specifies unlimited
retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example: 0 =
0
00, 5 = 005, 20 = 020, etc.
3. Go to page 54 and scan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in Appendix D, Keypad,
that represent the number which was determined in the steps above. You
wil
l hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry
string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table 32 for some examples of how to set
this feature.
Table 32. ACK NAK Retry Count Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
Disable Retry
Count
3 Retries 54 Retries Unlimited Retries
2 Pad with leading zero(es)
000 003 054 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ACK NAK RETRY COUNT SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘3’ ‘0’, ‘5’ and ‘4’ ‘2’, ‘5’ and ‘5
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents