Enter/Exit Programming Mode Reading Parameters
102
Gryphon™ I GD44XX
/
GBT4400/GM440X
Stand Illumination Control
Controls the illumination status while the reading mode is stand mode and the reader is
attempting to detect objects.
Motion Still Timeout
Motion Still Timeout specifies the waiting time after which no motions is detected. When no
motion is detected for period of time longer than the set Motion Still Timeout period, the
scanner assumes it is in a motionless condition. The selectable setting are from 500 to 25,500
milliseconds in 100 millisecond increments. The default is 2 seconds. This option relates to
such features and the Aimer On timing and Stand Mode Object Sense scanning with respect to
motion. See page 288 in "References" for detailed information on setting this feature.
Stand Illumination Control = OFF
Stand Illumination Control = ON
Stand Illumination Control = Dim
DEFAULT
$CSMIL00(CR)
$CSMIL01(CR)
$CSMIL02(CR)
Select Motion Still Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
a
t left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
ba
r code again.
Make a mistake? Scan the CANCEL bar code to abort
and not
save the entry string. You can then start again at
the beginning.
CANCEL
$CMOTO/r
~
DEFAULT
14 = Motion Still Timeout for 2 seconds