Code 93 Enter/Exit Programming Mode
Product Reference Guide
191
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift ch
aracters. The length
does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of
0 specifies to ignore this length (only one fixed length).
Table 20 provides examples for setting Length 2. See page 265 for detailed instructions on
setting this feature.
Table 20. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Le
ngth)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
$CC9L2
~
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic Gryphon Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon Series and is the answer not in the manual?

Datalogic Gryphon Series Specifications

General IconGeneral
ConnectivityUSB, RS-232, Keyboard Wedge, Bluetooth
Scan PatternSingle-line or omnidirectional
Humidity5% to 95% non-condensing
Decode Capability1D and 2D barcodes
Ambient LightUp to 100, 000 lux