Enter/Exit Programming Mode Codabar
168
Gryphon™ I GD44XX
/
GBT4400/GM440X
Codabar Check Character Transmission
Enable this option to transmit the check character along with Codabar bar code data.
Codabar Start/Stop Character Transmission
Enable this option to enable/disable transmission of Codabar start and stop characters.
Codabar Check Character Transmission = Don’t Send
Codabar Check Character Transmission = Send
$CCBCT00(CR)
$CCBCT01(CR)
DEFAULT
Codabar Start/Stop Character Transmission = Don’t
Transmit
Codabar Start/Stop Character Transmission = Transmit
$CCBSS00(CR)
$CCBSS01(CR)