Scanning Features
Product Reference Guide
283
Multiple Labels Ordering by Code Symbology
This feature Specifies the transmission ordering by symbology type, when Multiple Labels per
Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string
to 12 characters if not using all six symbologies.
The labels are ordered first as specified in the out
put mask. Labels present in the volume but not
specified will be transmitted as unspecified symbologies in random order as allowed by the
reading time sequence. For each label decoded in the volume the reader signals the standard
beeper and LED indications.
To specify the symbology order:
1. Determine the symbologies and or
der you want to specify.
2. Use Table 45 on page 284 to find the hex
values for up to six symbologies.
3. Go to page 108 and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
4. Scan the bar code: “SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDER-
ING”.
5. Scan the appropriate two alphanumeric
characters from the keypad in Appendix D, Key-
pad, that represent the desired character/value in step 2 above.
6. Scan zeroes if needed to make a 12-character string.
7. When finished, scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Pro-
gramming Mode.
This completes the procedure. See Tabl e 44 for some examples of how to set this feature.
Table 44. Multiple Labels Ordering by Code Symbology Examples
Table 45 on page 284 shows the hex value associated with each symbology.
STEP ACTION EXAMPLES
1 Desired symbology
Code 39 Data Matrix Code 128 Aztec
2 Hex equivalent from
Table 45
24 0E 0C 4E
3 Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING
5
Scan Two Characters From
Appendix D, Keypad
‘2’ and ‘4’ ‘0’ and ‘E’ ‘0’ and ‘C’ ‘4’ and ‘E’
RESULT
0x240E0C4E0000
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic Gryphon Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon Series and is the answer not in the manual?

Datalogic Gryphon Series Specifications

General IconGeneral
ConnectivityUSB, RS-232, Keyboard Wedge, Bluetooth
Scan PatternSingle-line or omnidirectional
Humidity5% to 95% non-condensing
Decode Capability1D and 2D barcodes
Ambient LightUp to 100, 000 lux

Related product manuals