RS-232/USB-Com Interfaces Enter/Exit Programming Mode
Product Reference Guide
47
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the beginning of the next.
The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies
no delay.
See page 263 for more information.
Beep On ASCII BEL
When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial
line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
Intercharacter Delay = No Delay
Select Intercharacter Delay Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the
bar code at left followed by the digits from the
Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). End by
scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again at
the beginning.
CANCEL
Beep On ASCII BEL = Disable
Beep On ASCII BEL = Enable
$CR2IC00(CR)
$CR2IC
~
DEFAULT
00 = No Intercharacter Delay
$CR2BB00(CR)
DEFAULT
$CR2BB01(CR)

Table of Contents

Other manuals for Datalogic Gryphon Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon Series and is the answer not in the manual?

Datalogic Gryphon Series Specifications

General IconGeneral
ConnectivityUSB, RS-232, Keyboard Wedge, Bluetooth
Scan PatternSingle-line or omnidirectional
Humidity5% to 95% non-condensing
Decode Capability1D and 2D barcodes
Ambient LightUp to 100, 000 lux

Related product manuals