Code 39 Enter/Exit Programming Mode
Product Reference Guide
135
Code 39 Quiet Zones
This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas
at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label.
Code 39 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 39
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Code 39 Quiet Zones = Quiet Zones on two sides
Code 39 Quiet Zones = Small Quiet Zones on two sides
$CC3LO02(CR)
$CC3LO03(CR)
DEFAULT
Code 39 Length Control = Variable Length
Code 39 Length Control = Fixed Length
DEFAULT
$CC3LC00(CR)
$CC3LC01(CR)