Enter/Exit Programming Mode Plessey
200
Gryphon™ I GD44XX
/
GBT4400/GM440X
Plessey Set Length 2
This feature specifies one of the bar code lengths for Plessey Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift ch
aracters. The length
does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of
0 specifies to ignore this length (only
one fixed length).
Table 24 provides examples for setting Length 2. See page 265 for detailed instructions on
setting this feature.
Table 24. Plessey Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Le
ngth)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT PLESSEY LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters