Enter/Exit Programming Mode Interleaved 2 of 5 (I 2 of 5)
154
Gryphon™ I GD44XX
/
GBT4400/GM440X
I 2 of 5 Check Character Transmission
Enable this option to transmit the check character along with I 2 of 5 bar code data.
I 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
I 2 of 5 Check Character Transmission = Don’t Send
I 2 of 5 Check Character Transmission = Send
$CI2CT00(CR)
$CI2CT01(CR)
DEFAULT
I 2 of 5 Length Control = Variable Length
I 2 of 5 Length Control = Fixed Length
DEFAULT
$CI2LC00(CR)
$CI2LC01(CR)