EAN 13 (Jan 13) Enter/Exit Programming Mode
Product Reference Guide
119
EAN-13 Flag 1 Character
Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the
first character of the label.
EAN-13 ISBN Conversion
This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978
to ISBN labels.
EAN-13 Flag 1 Char= Don’t transmit
EAN-13 Flag 1 Char= Transmit
$C3BF100(CR)
$C3BF101(CR)
DEFAULT
EAN-13 ISBN Conversion = Disable
EAN-13 ISBN Conversion = Convert to ISBN
DEFAULT
$C3BIS00(CR)
$C3BIS01(CR)