Enter/Exit Programming Mode Aztec Code
204
Gryphon™ I GD44XX
/
GBT4400/GM440X
Aztec Code
Aztec Code Enable / Disable
Enables/disables the ability of the reader to decode Aztec Code labels.
Aztec Code Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Aztec Code = Disable
Aztec Code = Enable
DEFAULT
$CAZEN00(CR)
$CAZEN01(CR)
Aztec Code Length Control = Variable Length
Aztec Code Length Control = Fixed Length
DEFAULT
$CAZLC00(CR)
$CAZLC01(CR)