Reading Parameters Enter/Exit Programming Mode
Product Reference Guide
103
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See
page 281 in “References” for detailed information on setting this feature.
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See
page 282 in “References” for detailed information on setting this feature.
Select Flash ON Time Setting
To configure this feature, sc
an the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
a
t left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar c
ode again.
Make a mistake? Scan the CANCEL bar code to abort
and not
save the entry string. You can then start again at
the beginning.
CANCEL
DEFAULT
10 = Flash is ON for 1 Second
Select Flash OFF Time Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
a
t left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar c
ode again.
Make a mistake? Scan the CANCEL bar code to abort
and not
save the entry string. You can then start again at
the beginning.
CANCEL
DEFAULT
06 = Flash is OFF for 600ms