GS1 DataBar™ Expanded Enter/Exit Programming Mode
Product Reference Guide
183
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the GS1
DataBar™ Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
GS1 DataBar™ Expanded Length Control = Variable
Length
GS1 DataBar™ Expanded Length Control = Fixed Length
DEFAULT
$CXBLC00(CR)
$CXBLC01(CR)