Enter/Exit Programming Mode Plessey
198
Gryphon™ I GD44XX
/
GBT4400/GM440X
Plessey Check Character Transmission
Enables/disables transmission of an MSI check character.
Plessey Length Control
This feature specifies either variable length decoding or fixed length decoding for the Plessey
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Plessey Check Character Transmission = Disable
Plessey Check Character T
ransmission = Enable
$CPLCT00(CR)
$CPLCT01(CR)
DEFAULT
Plessey Length Control = Variable Length
Plessey = Fixed Length
DEFAULT
$CPLLC00(CR)
$CPLLC01(CR)