Enter/Exit Programming Mode Motion Features
252
Gryphon™ I GD44XX
/
GBT4400/GM440X
Motion Sensitivity
Defines discrete set of levels for scanner motion sensitivity when in handheld use.
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader is in a motionless
condition. The selectable range is 500 msec to 25.5 Seconds. When no motion event is detected
for a period of time longer than this timeout, the software assumes the reader is in a motionless
condition. This normally results in returning the scanner to Stand Mode. This option relates to
such features as Aimer On and Stand Mode Object Sense scanning with respect to motion. See
"M
otionless Timeout" on page 288 in References.
Motion Sensitivity = Low
Motion Sensitivity = Medium
Motion Sensitivity = High
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
a
t left followed by three digits from the Alphanumeric
characters in
Appendix D Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
ba
r code again.
Make a mistake? Scan the CANCEL bar code to abort
and not
save the entry string. You can then start again at
the beginning.
CANCEL
DEFAULT
020 = Motionless Timeout = 2 seconds