294
Gryphon™ I GD44XX
/
GBT4400/GM440X
Item Description
User Environment GD44XX Models GBT Models
Operating Tem-
perature
32° to 131° F (0° to 55°
C)
32° to 122° F (0° to 50° C)
Charging Tem-
perature
N/A 32° to 104° F (0° to 40° C)
Storage Tem-
perature
-4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity, non-condensing
Drop Specifica-
tions
Scanner withstands 18 drops from 1.8 meters (5.9 feet) to concrete
Ambient Light
Immunity
Up to 100,000 Lux
Contaminants
Spray/Rain/
Dust/Particu-
lates
IEC 529-IP52
ESD Level
16 KV
Regulatory
Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950
EMI/RFI
GD44XX Models GBT Models GM44 433 Models
North America (FCC) :
Part 15 Class B; Canada (
IC) : ICES-003 Class B;
Russia ( Gost); European
Union EMC Directive;
VCCI-Japan; Korean KCC;
Taiwan EMC (BSMI);
Australia (ACMA)
Europe - CE; Australia -
C-tick; Rus
sia – GOST;
USA/CANADA – FCC/IC;
Japan – JRF/VCCI; Mex-
ico - NOM + Cofetel;
Sout
h Korea - KCC; Bra-
zil - ANATEL; Argentina -
CN
C; China - SRRC;
Malaysia - SIRIM; Indo-
nesia, Singapore - IDA;
T
aiwan - NCC; Philip-
pines - NTC
Europe - CE; Australia -
C-tick; Russia – GO
ST;
Singapore - IDA; China -
SRRC; Brazil - ANATEL
GM44 910 Models
USA/CANADA – FCC/IC;
Mexico - NOM + Cofe-
tel;
Laser Safety
IEC Class 2
Radiation 1 mW Avg., Emitted wavelength 650 nm, 12ms pulse, Beam Diver-
gence 8.4 deg x 8.1 deg ("plus" pattern).
Complies with FDA performance standards f
or laser products except for devia-
tions pursuant to Laser Notice No. 50, dated June 24, 2007.