EasyManua.ls Logo

Dell SC8000 - Clean up Test Volumes

Dell SC8000
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Verify Connectivity and Failover
Dell Compellent 167
d Afterthecopyfinishes,turnonthecontroller.
e Wait3minutesandverifythatthecontrollerhasfinishedstarting.
f Rebalancetheports.
3 Manuallyshutdownthesecond controllerwhilecopyingdatatoTestVol2toverifythat
IOisnotinterruptedbythefailoverevent.
a CopytheTestfoldertothe
TestVol2volume.
b Duringthecopyprocess,shutdownthesecondcontroller(thecontrollerthrough
whichthevolumeismapped).
c Verifythatthecopyprocesscontinuesafterthecontrollerisshutdown.
d Afterthecopyfinishes,turnonthecontroller.
e Wait3minutesandverifythatthecontrollerhasfinished
starting.
f Rebalancetheports.
Test MPIO
IfthenetworkenvironmentandserversareconfiguredforMPIO,performteststomake
surethatfailedpathsdonotinterruptIO.
1 Create aTestfolderontheserverandcopyatleast2GBofdataintoit.
2 MakesurethattheFCoriSCSIserverisconfiguredtouseload
balancingMPIO(round
robin).
3 ManuallydisconnectapathwhilecopyingdatatoTestVol1toverifythatMPIOis
functioningcorrectly.
a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,disconnectoneofthepathsandverifythatthecopy
processcontinues.
c Reconnecttheport.
4 RepeatStep 3as
necessarytotestadditionalpaths.
5 (Du alcontrollerStorageCenter)Restartthecontrollerthatcontainstheactivepath
whileIOisbeingtransferred.
6 If theStorageCenterisnotinaproductionenvironment,restarttheswitchthatcontains
theactivepathwhileIOisbeingtransferred.
Clean up Test Volumes
Aftertestingiscomplete,deletethevolumesusedfortesting.

Table of Contents

Related product manuals