Chapter 11 Summary of Parameter Settings
MH300
Pr. Parameter Name
Setting Range
Default
14-57
IGBT temperature at
malfunction 3
-3276.7–3276.7ºC Read only
14-58
Output frequency at
malfunction 4
0.00–599.00 Hz Read only
14-59
DC voltage at malfunction
4
0.0–6553.5 V Read only
14-60
Output current at
malfunction 4
0.00–655.35 Amps Read only
14-61
IGBT temperature at
malfunction 4
-3276.7–3276.7ºC Read only
14-62
Output frequency at
malfunction 5
0.00–599.00 Hz Read only
14-63
DC voltage at malfunction
5
0.0–6553.5 V Read only
14-64
Output current at
malfunction 5
0.00–655.35 Amps Read only
14-65
IGBT temperature at
malfunction 5
-3276.7–3276.7ºC Read only
14-66
Output frequency at
malfunction 6
0.00–599.00 Hz Read only
14-67
DC voltage at malfunction
6
0.0–6553.5 V Read only
14-68
Output current at
malfunction 6
0.00–655.35 Amps Read only
14-69
IGBT temperature at
malfunction 6
-3276.7–3276.7ºC Read only
14-70 Fault record 7 Refer to fault record Pr.06-17–06-22 0
14-71 Fault record 8 Refer to fault record Pr.06-17–06-22 0
14-72 Fault record 9 Refer to fault record Pr.06-17–06-22 0
14-73 Fault record 10 Refer to fault record Pr.06-17–06-22 0
14-74
Over-torque detection
action (motor 3)
0: No function
1: Continue operation after over-torque detection during
constant speed operation
2: Stop after over-torque detection during constant speed
operation
3: Continue operation after over-torque detection during
RUN
4: Stop after over-torque detection during RUN
0
14-75
Over-torque detection
level (motor 3)
10–250%
(100% corresponds to the rated current of the drive)
120