EasyManua.ls Logo

Delta MH300 Series - Page 493

Delta MH300 Series
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 12 Description of Parameter Settings
MH300
12
.1-09-6
09-60
Communication Card Identifications
Default: Read Only
Settings 0: No communication card
1: DeviceNet Slave
2: PROFIBUS-DP Slave
3: CANopen Slave / Master
5: EtherNet/IP Slave
6: EtherCAT
10: Backup Power Supply
12: PROFINET
09-61
Firmware Version of Communication Card
09-62
Product Code
09-63
Error Code
Default: Read Only
Settings Read only
09-70
Communication Card Address (for DeviceNet or PROFIBUS)
Default: 1
Settings DeviceNet: 0–63
PROFIBUS-DP: 1–125
09-71
DeviceNet Speed Setting (for DeviceNet)
Default: 2
Settings Standard DeviceNet:
0: 125 Kbps
1: 250 Kbps
2: 500 Kbps
3: 1 Mbps (Delta Only)
Non-standard DeviceNet (Delta only) :
0: 10 Kbps
1: 20 Kbps
2: 50 Kbps
3: 100 Kbps
4: 125 Kbps
5: 250 Kbps
6: 500 Kbps
7: 800 Kbps

Table of Contents