EasyManua.ls Logo

Denso BHT-1306BWB - Detailed Settings for Standard 2 of 5 (STF)

Denso BHT-1306BWB
256 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
99
Barcode Handy Terminal
“8: STF”: Detailed settings for Standard 2 of 5 (STF)
1. Select “8: STF” at the SET BARCODE menu and then press the ENT
key.
The SET STF screen is displayed.
“1: MIN”:
Set minimum number of digits of STF.
Setting range: 1–99
“2: MAX”:
Set maximum number of digits of STF.
Setting range: 1–99
- Point - Make sure that the minimum number of digits is less than the maximum number of digits. I
f
the value of minimum number of digits is larger than the maximum number of digits, erro
r
occurs during the reading.
“3: CD CHECK”:
“ON”: Reading is performed only when the check digits are correct. Reading becomes
impossible if check digits are incorrect or missing.
“OFF”: Reading is performed regardless of the use of check digits.
“4: TYPE”:
“BOTH”: Enable both normal and short STF reading.
“NORMAL”: Enable normal STF reading.
“SHORT”: Enable short STF reading.
2. Use the cursor keys ([] []) or numerical keys ([1] [2] [3] [4]) to select the item to be set and
press the ENT key.
3. Use the cursor keys ([ ] [ ]) to select settings value.
4. Press the ENT key or BS/C key for the settings value to be valid and then return to the SET
BARCODE screen.

Table of Contents