EasyManua.ls Logo

DURKOPP ADLER 745-35-10 S - Page 126

DURKOPP ADLER 745-35-10 S
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Light barriers
124 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Fig. 106: Setting the light barriers for the left and the right flap rest (2)
To set the light barriers for the left and the right flap rest:
1. Insert the sewing material.
2. Open the menu Service > Machine test and press the button
Align light barriers .
3. Swing the folding station out.
4. Press the button.
Reference run is carried out.
5. Press the
button and select the desired transport clamp position.
The light barriers must be aligned with the transport clamp position.
6. Press the button.
The flap clamp opens.
7. Press the button.
The needles are switched on.
8. Use the handwheel to turn the needles downward with the direction of
rotation until they are approx. 2 mm above the sewing material.
9. Insert the template (1) (straight pocket) such that line (3) points to the
left needle and is parallel to the right transport clamp.
10. Press the button.
The flap clamp closes.
(2) - Strip of adhesive tape (3) - Line

Table of Contents

Other manuals for DURKOPP ADLER 745-35-10 S

Related product manuals