Light barriers
124 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Fig. 106: Setting the light barriers for the left and the right flap rest (2)
To set the light barriers for the left and the right flap rest:
1. Insert the sewing material.
2. Open the menu Service > Machine test and press the button 
Align light barriers .
3. Swing the folding station out.
4. Press the  button.
 Reference run is carried out.
5. Press the 
 button and select the desired transport clamp position.
 The light barriers must be aligned with the transport clamp position.
6. Press the  button.
 The flap clamp opens.
7. Press the  button.
 The needles are switched on.
8. Use the handwheel to turn the needles downward with the direction of 
rotation until they are approx. 2 mm above the sewing material.
9. Insert the template (1) (straight pocket) such that line (3) points to the 
left needle and is parallel to the right transport clamp.
10. Press the  button.
 The flap clamp closes.
(2) - Strip of adhesive tape (3) - Line