Stacker
164 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Information
If the switch actuation point is set too early, the pieces will not be clamped 
safely and may fall to the ground. Check the optimal switch actuation point by 
performing stacking operations with workpieces and correct it if necessary.
Fig. 145: Setting the throw-over stacker (3)
4. Clamping bracket (4) opens.
 The switch (8) is pressed when the clamping bracket (4) is at a 
distance of (a) = 60 - 80 mm from the swivel bracket (2).
5. Loosen the screw and adjust the switch cam (9) by turning.
Important
If the switch actuation point is set too early, the throw-over bracket (3) may 
collide with the clamping bracket (4) during the last section of the backward 
movement. Check the optimal switch actuation point by performing stacking 
operations with workpieces and correct it if necessary.
Fig. 146: Setting the throw-over stacker (4)
(8) - Switch (9) - Switch cam
(10) - Switch cam
(11) - Switch
(12) - Cylinder