Characteriscs
GXS450/
2600
GXS450/
4200
GXS750
GXS750/
2600
GXS750/
4200
Units
Dry pump motor rang 11 11 22 22 22 kW
Mechanical booster
motor rang
7.5 7.5 - 7.5 7.5 kW
Current rang
(200 - 230 V systems)
65 65 120 140 135 A
Current rang
(380 - 460 V systems)
34 34 60 78 74 A
Recommended branch
circuit protecon UL
(200 - 230 V systems)
80 80 150 170 160 A
Recommended branch
circuit protecon IEC
(200 - 230 V systems)
65 65 120 140 135 A
Recommended branch
circuit protecon UL
(380 - 460 V systems)
40 40 75 95 90 A
Recommended branch
circuit protecon IEC
(380 - 460 V systems)
35 35 63 80 75 A
Min cable size for 200 -
230 V systems (or
corresponding AWG size)
16 (4) 16 (4) 35 (2) 50 (1/0) 50 (1/0)
mm
2
(AWG)
Min cable size for 380 -
460 V systems (or
corresponding AWG size)
10 (6)† 10 (6)† 16 (4) 25 (4) 25 (4)
mm
2
(AWG)
Mains connector for 200
- 230 V systems
Han
®
100 A
module
Han
®
100 A
module
Han
®
200 A
module
Han
®
200 A
module
Han
®
200 A
module
-
Mains connector for 380
- 460 V systems
Han
®
100 A
module
Han
®
100 A
module
Han
®
100 A
module
Han
®
100 A
module
Han
®
100 A
module
-
* The minimum geometric wire gauge for Han
®
K 4/4 is 6 mm
2
and minimum AWG size is 8 AWG.
† The minimum geometric wire gauge for Han
®
100A module is 10 mm
2
and minimum AWG size is
6 AWG.
Page 21
M58800880_H - Technical data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards GXS Series and is the answer not in the manual?

Edwards GXS Series Specifications

General IconGeneral
BrandEdwards
ModelGXS Series
CategoryWater Pump
LanguageEnglish

Related product manuals