WARNING:
Risk of electric shock. Isolate the electrical supply before disconnecng the electrical
supply cable from the dry pumping system.
WARNING:
Ensure that the dry pumping system and the electrical supply cable are suitably
protected against earth (ground) faults and that the earth (ground) conductor of the
electrical supply cable is longer than the phase conductors in the connector.
WARNING:
A second protecve earth (ground) conductor (with a cross-seconal area at least
equal to the phase conductor size up to 16 mm
2
) must be ed to the protecve
earth (ground) stud. Refer to Figure: The controls/connectors on the rear of the pump
(system with rear exhaust and castors/levelling feet ed) item 15.
WARNING:
All connecons to the interface control must be double insulated or have the
equivalent protecon. Do not connect the voltages greater than 30 V a.c. or 60 V d.c.
to the control/interface connecons as the interface control will not provide
protecon against electric shock.
WARNING:
The power wiring to the dry pumping system must be properly protected.
CAUTION:
All dry pumping systems are supplied already congured for an electrical supply. The
dry pumping system cannot be recongured between the low voltage (200 V to
230 V) and high voltage (380 V to 460 V) ranges.
CAUTION:
This is an industrial (Class A) product as dened by EN61326. To ensure compliance
with European Electromagnec Compability (EMC) requirements for EMC
emissions, please note that it is not intended for use in domesc buildings, or in the
properes directly connected to an electrical supply network which also supplies
domesc buildings.
CAUTION:
Do not connect voltages greater than specied in Table: Electrical connecons to the
control/interface connecons as it may cause damage to the interface control.
Page 38
M58800880_H - Installaon