▪ Push back both the levers (item 4) to release the protecve cover.
▪ Remove the protecve cover and t the electrical supply cable.
▪ Pull both levers back towards the user to lock the electrical supply cable connector
in place.
▪ Push the locking mechanism down as far as possible and then push to the right so
that it prevents the le hand lever from actuang.
▪ Tighten the locking screw (item 3) to rmly hold the locking mechanism in place.
▪ Connect the other end of the electrical supply cable to the electrical supply
through a suitable isolator.
For the locking mechanism for all GXS750 dry pumping systems, refer to Figure:
Electrical connector locking mechanism for the GXS750 systems.
This locking mechanism is held in a place by two M5 locking nuts and requires use of a
suitable spanner to release. Referring to Figure: Electrical connector locking mechanism
for the GXS750 systems, the dry pumping system is supplied with a protecve cover
(item 1) ed and the locking mechanism (item 3) may be applied. The protecve cover
is held in place by two locking levers (item 2). Follow these instrucons to t the
electrical supply cable:
▪ Slacken o the two locking nuts (item 4) by few turns to loosen the locking
mechanism.
▪
Move the locking mechanism (item 3) to the right as far as possible so that it clears
the right hand lever (item 2).
▪ Push back both the levers (item 2) to release the protecve cover.
▪ Remove the protecve cover and t your electrical supply cable.
▪
Pull both levers back towards you to lock your electrical supply cable connector in
place.
▪ Push the locking mechanism as far as possible to the le so that it prevents the
right hand lever from actuang.
▪
Tighten the locking nuts (item 4) to rmly hold the locking mechanism in place.
▪
Connect the other end of the electrical supply cable to the electrical supply
through a suitable isolator.
If further informaon is required about connecng the electrical supply, contact us for
advice.