Step Description Command Keys
10 Set the interval after which the BFD
message is sent to the neighbor.
On the interface
(optionally)
esr(config-if-gi)# ip bfd idle-tx-
interval <TIMEOUT>
<TIMEOUT> – interval after
which the BFD packet should
be sent, takes values in
milliseconds in the range of
[200..65535] for
ESR-1000/1200/1500/1511
/1700/3100 and [300..65535]
for ESR-10/12V(F)/14VF/
20/21/100/200.
Default: 1 second
11 Set the minimum interval after which
the neighbor should generate BFD
message.
On the interface
(optionally)
esr(config-if-gi)# ip bfd min-rx-
interval <TIMEOUT>
<TIMEOUT> – interval after
which the BFD message should
be sent by the neighbor, takes
values in milliseconds in the
range of [200..65535] for
ESR-1000/1200/1500/1511
/1700/3100 and [300..65535]
for ESR-10/12V(F)/
20/21/100/200
By default:
300 ms on
ESR-10/12V(F)/14VF/
20/21/100/200
200 ms on
ESR-1000/1200/1500
/1511/1700/3100
12 Set the minimum interval after which
the BFD message is sent to the
neighbor.
On the interface
(optionally)
esr(config-if-gi)# ip bfd min-tx-
interval <TIMEOUT>
<TIMEOUT> – interval after
which the BFD message should
be sent by the neighbor, takes
values in milliseconds in the
range of [200..65535] for
ESR-1000/1200/1500/1511
/1700/3100 and [300..65535]
for ESR-10/12V(F)/
20/21/100/200
By default:
300 ms on
ESR-10/12V(F)/14VF/
20/21/100/200
200 ms on
ESR-1000/1200/1500
/1511/1700/3100