EasyManua.ls Logo

ELTEX ESR Series - 18 BRAS (Broadband Remote Access Server) management; 18.1 Configuration algorithm; 18.2 Example of configuration with SoftWLC

ELTEX ESR Series
575 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ESR-Series. User manual
540
18 BRAS (Broadband Remote Access Server) management
Configuration algorithm
Example of configuration with SoftWLC
Example of configuration without SoftWLC
18.1 Configuration algorithm
Step Description Command Keys
1 Add RADIUS server to the list of used
servers and switch to its configuration
mode.
esr(config)# radius-server host
{ <IP-ADDR> | <IPV6-ADDR> }
[ vrf <VRF> ]
esr(config-radius-server)#
<IP-ADDR> – RADIUS server IP
address, defined as
AAA.BBB.CCC.DDD where each
part takes values of [0..255];
<IPV6-ADDR> – RADIUS server
IPv6 address, defined as
X:X:X:X::X where each part
takes values in hexadecimal
format [0..FFFF].
<VRF> – VRF instance name,
set by the string of up to 31
characters.
2 Set the password for authentication on
remote RADIUS server.
esr(config-radius-server)# key
ascii-text
{ <TEXT> | encrypted
<ENCRYPTED-TEXT> }
<TEXT> – string of [8..16] ASCII
characters; <ENCRYPTED-
TEXT> – encrypted password,
[8..16] bytes size, set by the
string of [16..32] characters.
3 Create AAA profile. esr(config)# aaa radius-profile
<NAME>
<NAME> – server profile name,
set by the string of up to 31
characters.
4 Specify RADIUS server in AAA profile. esr(config-aaa-radius-profile)#
radius-server host
{ <IP-ADDR> | <IPV6-ADDR> }
<IP-ADDR> – RADIUS server IP
address, defined as
AAA.BBB.CCC.DDD where each
part takes values of [0..255];
<IPV6-ADDR> – RADIUS server
IPv6 address, defined as
X:X:X:X::X where each part
takes values in hexadecimal
format [0..FFFF].
5 Create DAS server. esr(config)# das-server <NAME> <NAME> – DAS server name,
set by the string of up to 31
characters.

Table of Contents