EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 141
FIP-8
Panel Message
Photocondctr Trouble
Possible parts that caused the error
Troubleshooting
Photoconductor Unit PWBA MCU
HARNESS ASSY MAIN LV/HVPS
Step Check Yes No
1
Model check of Photoconductor Unit
Is a Photoconductor Unit that complies with
the specifications attached?
Go to Step [2]. Replace with a
Photoconductor
Unit that
complies with
the
specifications.
2
Attachment check of Photoconductor Unit
Re-attach Photoconductor Unit.
Does the error recur when the power is turned
ON?
Go to Step [3]. End of
procedure
3
Check after replacement of
Photoconductor Unit
Replace Photoconductor Unit.
Does the error recur when the power is turned
ON?
Go to Step [4]. End of
procedure
4
Power supply check to PWBA MCU
Are the following power voltages being
supplied to PWBA MCU from LV/HVPS?
J410-1J410-2: 3. 3 VDC
J410-3J410-4: 5 VDC
J410-5/6J410-7/8: 24 VDC
Replace PWBA
MCU. (p.404)
Go to Step [5].
5
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1J502-1
J410-2J502-2
J410-3J502-3
J410-4J502-4
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.
Step Check Yes No