EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 161
22
Operation check of CLUTCH ASSY FEED
Does CLUTCH ASSY FEED operate
normally?
Make a test print and confirm by the operating
noise.
Go to Step [30]. Go to Step [23].
23
Continuity check of HARNESS-ASSY
FEED MAIN
Disconnect P/J437 from PWBA TRAY
CONT.
Do all of the wiring below have normal
continuity?
J437-6P609-2
J437-7P609-1
Go to Step [24]. Replace
HARNESS-
ASSY FEED
MAIN.
24
Check of resistance value of CLUTCH
ASSY FEED
The winding resistance between the terminals
of CLUTCH ASSY FEED is 144± 10%
(20°C)?
Go to Step [25]. Replace
CLUTCH
ASSY FEED.
(p.461)
25
24 VDC power supply check to PWBA
TRAY 500
The voltage of P435-9/10435-7/8 on
PWBA TRAY 500 is 24 VDC?
Go to Step [9]. Go to Step [26].
26
Continuity check of HARNESS-ASSY FEED 1
Disconnect P/J435 from PWBA TRAY
CONT.
Do all of the wiring below have normal
continuity?
J435-7P608-4
J435-8P608-3
J435-9P608-2
J435-10P608-1
Go to Step [27]. Replace
HARNESS-
ASSY FEED 1.
(p.462)
Step Check Yes No
27
Continuity check of HARNESS ASSY MAIN
Disconnect P/J421 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J421-1J608-10
J421-2J608-9
J421-3J608-8
J421-4J608-7
Go to Step [28]. Repair broken
or shorted part.
28
24 VDC power supply check to PWBA MCU
Disconnect the P/J410 from PWBA MCU.
The voltage of P410-5/6 P410-7/8 P410-7/
8 on PWBA MCU is 24 VDC?
Replace PWBA
MCU. (p.404)
Go to Step [29].
29
Continuity check of HARNESS-ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.
30
Check of 24 VDC power supply to DRIVE
ASSY FEED
The voltage of P437-4P437-5 on PWBA
TRAY CONT is 24 VDC?
Go to Step [31]. Go to Step [25].
31
Continuity check of HARNESS-ASSY
FEED MAIN
Disconnect P/J437 from PWBA TRAY 500.
Do all of the wiring below have normal
continuity?
J437-5J440-1
J437-4J440-2
J437-2J440-4
J437-1J440-5
Go to Step [8]. Replace
HARNESS-
ASSY FEED
MAIN.
Step Check Yes No